Liquid-cooled commercial & industrial energy storage cabinets in 125kW / 522kWh and 125kW / 261kWh configurations — integrated AC and DC design with cloud monitoring.
Models
- Liquid Cooling — 125kW / 522kWh
- Liquid Cooling — 125kW / 261kWh
Battery Pack (125kW / 522kWh)
- Cell Type: LFP (1P52S)
- Nominal Capacity: 314Ah
- Nominal Voltage: 166.4V
- Operating Voltage Range: 145.6~187.2V
- Nominal Energy: 52.2496kWh
- Dimensions (W×D×H): 792±1 × 247±1 × 1063±2 mm
- Product Weight: 340kg
Battery System (125kW / 522kWh)
- Configuration: LFP (1P260S)
- Charge / Discharge C-rate: ≤0.5C
- Nominal Voltage: 832V
- Operating Voltage Range: 702~936V
- Cooling Method: Liquid cooling
- IP Rating: ≥IP65
- DC System Efficiency: 93%
- Weight: approx. 4.2T
- Dimensions (W×D×H): 2000 × 1350 × 2380 mm (excluding lifting rings)
PCS (125kW / 522kWh)
- AC Connection: Three-phase four-wire
- Rated Power: 125kW
- DC Voltage Range: 615~950V (3W+PE) / 650~950V (3W+N+PE)
- Cooling Method: Forced air cooling
- Protection Rating: IP20
- Communication: CAN / RS485
- Full-load Altitude: ≤2000m (derating above)
System (125kW / 261kWh)
- System Capacity: 261kWh
- Cell Capacity: 314Ah (LFP)
- System Configuration: 1P260S
- Rated Voltage: 832VDC
- DC Voltage Range: 728~936VDC
- Charge / Discharge C-rate: 0.5P
AC Parameters (125kW / 261kWh)
- Rated Power: 125kW
- Rated Voltage: 380V, -15% ~ +10%
- Connection: 3P4W+PE
- Rated Frequency: 50 / 60Hz
- Power Factor: ≤3% (at rated power)
- Efficiency: max. 91%
Protection & Safety
- AC Side: Molded case circuit breaker
- DC Side: Disconnect switch + fuse
- Fire Suppression: Aerosol + water
Environmental & Physical
- Operating Temperature: -20~55°C (derating above 50°C)
- Altitude: ≤2000m
- Relative Humidity: 0~100%
- Weight: approx. 2.6T
- Dimensions (W×D×H): 1000 × 1400 × 2300 mm
- Protection Rating: IP54
- Cooling Method: Liquid cooling
- Communication: CAN / Ethernet / RS485 / dry contact
Note: specifications are subject to continuous product development — product form, parameters and performance are for reference only, please refer to the official product specification sheet.